Lambert Lx 24 Fi Instrukcia -

This long-form article serves as a complete instruction manual (instrukcia) covering installation prerequisites, control panel operation, daily use, parameter settings, maintenance schedules, error codes, and safety precautions. Always refer to the official Lambert documentation supplied with your unit, as regional gas and water regulations may vary. | Parameter | Value | |-----------|-------| | Type | C13, C33, C53 (concentric flue) | | Max heat output (heating) | 24 kW | | Min heat output (heating) | 5.4 kW | | DHW output (max) | 24 kW | | Efficiency class (heating) | ★★★ (ErP) | | NOx class | Class 6 | | DHW flow rate (ΔT=30°C) | ~11.4 l/min | | Inlet gas pressure (G20) | 20 mbar | | Electrical supply | 230V ~ 50Hz | | Power consumption | ~110 W | | IP rating | IPX4D | | Expansion vessel capacity | 6 l (pre-charge 1 bar) | | Max heating pressure | 3 bar | | DHW range | 30–60°C | | Heating flow temp range | 20–85°C |

Keep this article with your boiler’s official manual. For firmware-specific instructions or revised error codes, scan the QR code on the boiler’s side label or visit the Lambert support portal. lambert lx 24 fi instrukcia

| P-code | Function | Default | Adjust range | |--------|----------|---------|---------------| | P01 | Maximum CH power | 24 kW | 5–24 | | P02 | Pump post-circulation time | 3 min | 0–10 | | P03 | Antifreeze activation temp | 5°C | 3–10 | | P05 | DHW preheating (comfort) | 0 (off) | 0/1 | | P08 | Minimum CH power | 5.4 kW | 3–10 | | P10 | Fan speed offset | 0 | -5 to +5 | This long-form article serves as a complete instruction

A: Yes. The LX 24 FI works with volt-free (230V) or OpenTherm thermostats. Use terminals 3-4 for OpenTherm (if supported) or 1-2 for on/off. Use terminals 3-4 for OpenTherm (if supported) or

Changing parameters incorrectly can cause unstable combustion, sooting, or overheating. Only qualified technicians should modify P01, P08, P10. 8. Maintenance Schedule (For Long Life) To keep the warranty valid and ensure safety, follow this schedule:

| Code | Meaning | Likely cause | User action | |------|---------|--------------|--------------| | E01 | Low water pressure | <0.5 bar | Repressurise (see section 6) | | E02 | No flame ionization | Gas supply off, air in gas pipe | Check gas meter; reset once | | E03 | Overheating (NTC >105°C) | Pump failed, airlock | Wait 20 min; call engineer | | E04 | Flue blockage or fan fault | Bird nest, fan seized | Reset; if repeats → engineer | | E05 | External sensor fault | CH sensor short/open | Engineer required | | E09 | False flame signal | Electronics damp/wet | Power cycle; dry the area | | E10 | Internal NTC1 / NTC2 mismatch | Plate heat exchanger scaling | Engineer descaling needed | | E20 | Gas valve circuit error | Loose wiring, valve coil | Engineer |

A: Typically a dirty DHW plate heat exchanger or low flow rate. Clean the inlet filter first.