Dixell Xw60ls Manual «Linux»

For : | Parameter | Value | |-----------|-------| | Set | -18°C | | Hy | 2°C | | LS | -30°C | | US | -10°C | | dtE | 15°C | | MdF | 30 minutes | | idF | 8 hours | Conclusion The Dixell XW60LS is a reliable, flexible controller for commercial refrigeration. Mastering its parameter structure, wiring, and alarm handling allows technicians to optimize energy efficiency, protect compressors, and maintain precise temperature control. Always keep a copy of the official parameter list and use the Hot Key for rapid deployment across multiple units.

If configured as dor (door switch): opening the door stops fans and displays dA after a delay (parameter doA ). Closing the door restarts normal operation. The XW60LS flashes an alarm code on the display while the red LED blinks. dixell xw60ls manual

| i1P | Function | |-------|-----------| | oP | Door switch – normal open | | cL | Door switch – normal closed | | EAL | External alarm (generic) | | bAL | Serious alarm (compressor stop) | | PAL | Pressure switch alarm | | dor | Door switch with fan cut-off and defrost inhibition | For : | Parameter | Value | |-----------|-------|

Unlike simpler thermostats, the XW60LS combines temperature control, defrost scheduling, alarm management, and compressor protection into a single DIN-rail or panel-mounted device. | Parameter | Details | |-----------|---------| | Power Supply | 230VAC ±10% or 115VAC (depending on model suffix) | | Power Consumption | 3 VA max | | Display | 3-digit red LED, 0.56” height | | Inputs | 1 x NTC/PTC probe (PTC: 1KΩ, NTC: 10KΩ at 25°C) | | Digital Input | 1 x free voltage contact (configurable) | | Relay Outputs | Compressor (8A resistive), Defrost (8A), Fan (5A) | | Operating Temp | 0° to 55°C (32° to 131°F) | | Storage Temp | -20° to 70°C (-4° to 158°F) | | Enclosure | IP20 (front panel IP65) | | Dimensions | 74 x 32 x 59 mm (front panel: 74x32mm) | Physical Layout & Terminal Connections The XW60LS features a front membrane keypad with 4 buttons and a 3-digit display. Below is the terminal block assignment (typical for XW60LS): If configured as dor (door switch): opening the

| Parameter | Value | |-----------|-------| | Set | 2°C | | Hy | 4°C (cut-in at 4°C, cut-out at 2°C) | | LS | -5°C | | US | 8°C | | tyP | 0 (electric) | | dtE | 8°C | | idF | 6 hours | | MdF | 20 minutes | | Fnc | 2 (fan with compressor, off during defrost) | | AC | 5 min |

For specific OEM variations (e.g., XW60LS with different probe curves or custom passwords), consult the original equipment manufacturer’s supplement. Refer to Emerson/Copeland’s official XW60LS – ISTR 03/11 installation manual or contact technical support with the controller’s full model code and firmware version (visible during power-up).